Global Livestock Equipment Manufacturer & Supplier
SHEWUYOU · Livestock Equipment
Integrated Equipment Solutions for Pig, Cattle & Poultry Farms

Ceiling-Mounted UV-C Surface Disinfection Unit

Product Name Ceiling-Mounted UV-C Surface Disinfection Unit
Product Image Ceiling-mounted UV-C surface disinfection unit
Product Overview The Ceiling-Mounted UV-C Surface Disinfection Unit is a fixed germicidal irradiation system designed for surface and air treatment in unoccupied livestock buildings, farm service rooms, veterinary areas, laboratories, feed processing facilities and agricultural production environments.

The unit uses high-output UV-C lamps operating around the germicidal wavelength of 253.7 nm. Direct UV-C radiation is projected toward exposed surfaces below and around the fixture, supporting supplementary hygiene procedures without applying liquid disinfectant to the treated area.

Ceiling installation keeps the equipment away from floor-level livestock equipment and daily traffic while providing a wide irradiation area. Multiple fixtures can be arranged according to room dimensions, mounting height, target surfaces and required UV-C dose.

The system can be incorporated into new pig farm construction, livestock building renovation and steel structure building projects, with fixture quantity and control configuration designed according to project requirements.
Key Features
  • Direct UV-C Irradiation: High-output UV-C lamps provide germicidal irradiation for exposed surfaces and surrounding air.
  • 253.7 nm UV-C Technology: Uses a wavelength commonly applied in professional germicidal UV systems.
  • Ceiling-Mounted Installation: Keeps floor areas clear and allows permanent integration into livestock and agricultural buildings.
  • Reflector-Assisted Output: Reflective internal surfaces help direct UV-C energy toward the required treatment zone.
  • No Liquid Application: Surface treatment is performed without spraying water or liquid disinfectant onto equipment.
  • Low Heat Generation: Suitable for many applications where chemical or high-temperature treatment is undesirable.
  • Corrosion-Resistant Options: Stainless steel configurations are available for humid and frequently cleaned environments.
  • Multiple-Unit Installation: Several fixtures can be installed and controlled together for larger rooms.
  • Space-Saving Design: Ceiling installation avoids interference with feeders, cages, pens, corridors and other farm equipment.
  • Project Customization: Lamp configuration, fixture quantity, mounting arrangement and control method can be selected according to project requirements.
Structural Components
  • UV-C Germicidal Lamp: Generates short-wave ultraviolet radiation for direct surface treatment.
  • Reflective Housing: Helps direct UV-C radiation toward the treatment area.
  • Protective Lamp Guard: Available to protect the lamp from accidental mechanical contact.
  • Fixture Body: Stainless steel or other UV-resistant material according to configuration.
  • Electronic Ballast: Provides stable electrical operation for the UV-C lamp.
  • Ceiling Mounting Brackets: Secure the unit to suitable building structures.
  • Power Connection: Connects the fixture to the building electrical system.
  • Control Interface: Optional centralized control can manage multiple UV-C fixtures.
  • Safety Accessories: Door interlocks, warning indicators, timers or occupancy detection can be incorporated according to the project.
Working Principle When activated, the UV-C lamp emits germicidal ultraviolet radiation toward exposed surfaces within its irradiation field. UV-C energy interacts with microorganisms and can inhibit their ability to reproduce when an appropriate UV dose reaches the target.

Reflective surfaces inside the fixture help direct the radiation toward the required treatment area. Fixture position, mounting height, exposure time and lamp output determine the UV-C dose received by each surface.

Direct UV-C treatment is line-of-sight technology. Surfaces hidden behind equipment, structural components or heavy contamination may receive insufficient UV exposure and should therefore be addressed through normal cleaning procedures and appropriate fixture planning.

Direct germicidal UV-C fixtures must normally operate only when people and animals are absent from the irradiated area. Appropriate safety controls should prevent accidental exposure of eyes and skin.
Technical Specifications
Product Type Ceiling-Mounted UV-C Surface Disinfection Unit
Primary Application Direct surface and air irradiation in unoccupied areas
UV-C Wavelength Approximately 253.7 nm
Lamp Type High-output germicidal UV-C lamp
Installation Method Ceiling-mounted or suspended according to project design
Housing Material Stainless steel configuration available
Reflector High-reflectivity aluminum configuration available
Protection Rating IP55 configuration available according to model
Lamp Protection Protective guard or shatter-resistant sleeve available
Control Method Switch, timer or centralized control according to project requirements
Electrical Configuration According to destination market and project requirements
Fixture Quantity Designed according to room dimensions, target UV dose and installation layout
Dimensions Available upon request
Applications
  • Empty pig houses between production cycles
  • Poultry house service and preparation areas
  • Livestock farm veterinary rooms
  • Farm laboratories
  • Equipment preparation rooms
  • Changing and hygiene rooms
  • Feed processing and storage areas
  • Egg handling and processing rooms
  • Livestock equipment storage rooms
  • Agricultural processing facilities
  • New pig farm construction projects
  • Steel structure livestock buildings
Customization Options
  • Lamp Configuration: UV-C lamp quantity and output can be selected according to the required treatment area.
  • Fixture Quantity: Multiple units can be arranged according to building dimensions and required UV coverage.
  • Mounting Method: Direct ceiling mounting or suspended installation is available according to building structure.
  • Housing Material: Stainless steel and other project-specific materials are available.
  • Protective Grid: Lamp protection can be added where required.
  • Centralized Control: Multiple fixtures can be connected to a common control system.
  • Timer Control: Automatic treatment cycles can be configured according to operating procedures.
  • Safety Interlock: Door switches or occupancy detection can be integrated to prevent accidental exposure.
  • Electrical Configuration: Voltage and electrical components can be adapted according to destination-market requirements.
  • Project Engineering: Designed according to local climate, room dimensions, mounting height and farm conditions.
Installation & Maintenance Installation should begin with an assessment of room dimensions, ceiling height, equipment layout and target surfaces. Fixtures should be positioned so that the required surfaces receive direct UV-C exposure with minimal obstruction.

For new pig farm construction or steel structure buildings, mounting points, electrical wiring and safety interlocks can be planned together with the building design. Multiple fixtures can be distributed throughout larger rooms to improve irradiation coverage.

Lamp surfaces and reflectors should be kept clean because dust and deposits can reduce UV output. Routine maintenance should include inspection of lamps, protective grids, mounting hardware, electrical components and safety controls.

UV-C lamp output decreases during service life. Lamps should therefore be replaced according to actual operating hours and the lamp manufacturer's maintenance recommendations.

Direct UV-C radiation can damage eyes and skin. The treatment area must be unoccupied during operation unless the specific system has been designed and validated for occupied-space use.
Project Cases Ceiling-mounted UV-C systems can be incorporated into livestock biosecurity projects where fixed, repeatable treatment of exposed surfaces is required.

In commercial pig farm projects, fixtures can be installed in empty service rooms, veterinary areas, preparation rooms and selected production areas for scheduled treatment after routine cleaning.

For poultry and agricultural processing projects, several ceiling-mounted UV-C units can be distributed across larger rooms and connected to centralized timers or safety controls.

Final fixture quantity and positioning should be determined from room geometry, lamp output, irradiation distance, shadowing and the required UV-C dose rather than room area alone.
Product FAQ Q: What wavelength does the UV-C unit use?
A: Professional germicidal configurations typically use high-output UV-C lamps with an emission peak around 253.7 nm.

Q: Can the unit disinfect both surfaces and air?
A: Direct UV-C primarily irradiates exposed surfaces, while surrounding air passing through the irradiated area can also receive UV-C treatment.

Q: Can people or livestock remain in the room during operation?
A: Direct UV-C configurations should normally operate only when personnel and animals are absent because direct exposure can damage eyes and skin.

Q: Is the system suitable for pig farms?
A: Yes. It can be used in suitable farm service rooms, veterinary areas, preparation areas and empty livestock spaces as part of a planned sanitation program.

Q: Does UV-C replace normal cleaning?
A: No. Physical cleaning should remove dust, manure and organic contamination before UV-C treatment because dirt and shadowing can reduce effective irradiation.

Q: Can several units be installed in one room?
A: Yes. Multiple fixtures can be arranged according to room dimensions, mounting height, equipment layout and required UV-C dose.

Q: Can the lamps be controlled automatically?
A: Yes. Timers, centralized control panels, door interlocks and other safety controls are available according to project requirements.

Q: Can the system be customized for steel structure livestock buildings?
A: Yes. Mounting arrangements, electrical connections and fixture layouts can be designed according to the steel structure building and farm conditions.
Product Gallery Ceiling-mounted UV-C germicidal disinfection fixture

Ceiling UV-C surface disinfection system installation

UV-C ceiling disinfection fixture installation area

Comments & Inquiries

Leave your questions or requirements below. We will reply as soon as possible.