| Product Name | Wall-Mounted Farm Ozone Disinfection Generator | ||||||||||||||||||||||
| Product Image | ![]() |
||||||||||||||||||||||
| Product Overview | The Wall-Mounted Farm Ozone Disinfection Generator is a compact air-treatment unit designed for controlled use in livestock buildings, farm service rooms, equipment rooms, storage areas and other agricultural environments where periodic ozone treatment and odor management are required. The reference configuration provides an ozone production rate of 3 g/h and incorporates timer-based control with automatic shutdown. A built-in diffusion fan distributes generated ozone through the treatment area, while the wall-mounted structure helps save floor space and keeps the equipment away from routine personnel and equipment traffic. The unit can be incorporated into commercial pig farm construction, poultry facilities, cattle farms and other livestock biosecurity projects. Equipment configuration, installation position and operating program can be selected according to room volume, ventilation conditions and project requirements. |
||||||||||||||||||||||
| Key Features |
|
||||||||||||||||||||||
| Structural Components |
|
||||||||||||||||||||||
| Working Principle | During operation, the ozone generation module converts oxygen contained in the incoming air into ozone. The integrated fan then promotes circulation and distributes ozone into the designated treatment area. The operator sets the required treatment period using the timing controller. The generator operates for the programmed cycle and automatically stops when the preset period is completed. Because ozone is a reactive gas, treatment effectiveness depends on room volume, ozone output, temperature, humidity, ventilation, contamination load and operating time. The operating program should therefore be established according to the actual livestock facility and project conditions. Ozone generators must not be operated in occupied spaces. People, livestock and other animals should be removed from the treatment area before ozone generation begins. After treatment, the area must be adequately ventilated and confirmed safe before re-entry. |
||||||||||||||||||||||
| Technical Specifications |
|
||||||||||||||||||||||
| Applications |
|
||||||||||||||||||||||
| Customization Options |
|
||||||||||||||||||||||
| Installation & Maintenance | Install the generator on a stable wall or structural support in a location that provides sufficient airflow around the air intake, fan and equipment housing. The mounting position should remain accessible for inspection and maintenance while avoiding areas exposed directly to water spray or physical impact. For livestock farm construction projects, electrical supply, mounting supports and room ventilation should be considered during the building design stage. The unit can be positioned in suitable service rooms or treatment areas according to the farm biosecurity layout. Routine maintenance should include checking the air intake, cooling fan, electrical connections, ozone generation components and control system. Dust and accumulated debris should be removed periodically to maintain suitable airflow and heat dissipation. Ozone is hazardous when inhaled at elevated concentrations. The generator should only be used according to an established safety procedure in unoccupied treatment areas. Personnel and animals must not remain in the treatment space during ozone generation. Ventilate the area thoroughly and verify safe conditions before re-entry. |
||||||||||||||||||||||
| Project Cases | The Wall-Mounted Farm Ozone Disinfection Generator can be incorporated into livestock farm biosecurity and sanitation programs where periodic treatment of unoccupied spaces is required. In commercial pig farm projects, wall-mounted units can be installed in suitable service rooms, equipment storage areas or designated treatment rooms. The elevated installation position helps preserve floor space and protects the equipment from routine traffic. For poultry, cattle and other livestock projects, ozone output and treatment schedules should be selected according to room volume, ventilation, building configuration and farm operating procedures. |
||||||||||||||||||||||
| Product FAQ | Q: What is the ozone output of the reference model? A: The reference wall-mounted model has a nominal ozone production rate of 3 g/h. Q: Can the generator be mounted directly on a wall? A: Yes. The reference configuration includes rear mounting points for wall installation. Q: Does the generator include automatic timing? A: Yes. The reference model provides timer-controlled operation and automatic shutdown after the programmed operating cycle. Q: Is the unit suitable for livestock farms? A: Yes. It can be used for controlled treatment applications in suitable pig farm, poultry farm, cattle farm and other agricultural spaces. Q: Can people or animals remain in the room while the generator is operating? A: No. Ozone generators should not be operated in occupied spaces. Personnel and animals must be removed before treatment, and the area must be adequately ventilated and confirmed safe before re-entry. Q: Can the ozone capacity be customized? A: Yes. Different output configurations can be selected according to room volume and project requirements. Q: Can the electrical configuration be supplied for different countries? A: Electrical specifications can be configured according to destination-market and project requirements. Q: Where should the unit be installed? A: It should be installed on a stable wall or structural support with sufficient ventilation and convenient maintenance access, away from direct water spray and impact areas. |
||||||||||||||||||||||
| Product Gallery | ![]() ![]() ![]() |