Global Livestock Equipment Manufacturer & Supplier
SHEWUYOU · Livestock Equipment
Integrated Equipment Solutions for Pig, Cattle & Poultry Farms

Mare Estrus & Ovulation Detector

Product Name Mare Estrus & Ovulation Detector
Product Image Mare Estrus and Ovulation Detector
Product Overview The Mare Estrus & Ovulation Detector is a portable electronic reproductive management instrument designed to assist horse breeders, veterinary reproduction specialists and artificial insemination technicians in monitoring the estrous cycle of mares.

The device measures changes in the electrical resistance of vaginal mucus. These electrical characteristics vary during the reproductive cycle and can provide an objective numerical reference for evaluating estrus progression and selecting an appropriate breeding or artificial insemination period.

Regular measurements and trend comparison can be particularly useful when behavioral estrus signs are weak, irregular or difficult to interpret. The instrument is suitable for equine breeding farms, stud farms, artificial insemination centers, veterinary clinics and reproductive research projects.
Key Features Estrus Monitoring for Mares: Designed to provide additional objective information during equine reproductive cycle monitoring.

Electrical Resistance Measurement: Measures changes in vaginal mucus electrical resistance associated with reproductive physiology.

Breeding-Time Assistance: Sequential readings can help identify a more suitable period for mating or artificial insemination.

Support for Silent or Atypical Estrus: Useful as an additional management tool when visible estrus behavior is weak or inconsistent.

Digital Measurement Display: A backlit LCD provides clear numerical readings for recording and comparison.

Animal Record Storage: Advanced configurations can store individual animal records and measurement history with date and time.

Portable Farm Operation: Battery-powered handheld design allows use in breeding barns, examination areas and mobile veterinary services.

Data Transfer: USB communication allows stored measurement information to be transferred to a computer for review and record management.
Structural Components Electronic Control Unit: Processes the electrical resistance measurement and displays the numerical result.

Long Veterinary Probe: Designed for controlled vaginal examination of mares and other large animals.

Electrode Tip: Sensing electrodes near the probe end contact reproductive tract mucus during measurement.

LCD Display: Shows measurement values, operating information and stored animal data according to configuration.

Membrane Keyboard: Provides simple navigation through measurement, memory and settings functions.

Battery Compartment: Supports independent field operation using replaceable batteries.

USB Interface: Used for data transfer and software updates on supported configurations.
Working Principle Hormonal changes during the mare's estrous cycle influence the composition and electrical properties of reproductive tract mucus. These changes can be detected by measuring electrical resistance.

During examination, the disinfected probe is carefully inserted into the vagina and positioned consistently according to the operating procedure. The electrodes at the probe tip contact the mucus and the instrument measures its electrical resistance.

Measurements are most useful when recorded regularly and evaluated as a trend rather than relying on a single reading. Changes in the measurement pattern can provide supporting information for identifying estrus and estimating a suitable breeding period.

The detector is a reproductive management aid and should be used together with behavioral observation, breeding records and professional veterinary examination when precise ovulation confirmation is required.
Technical Specifications
Product Type Electronic estrus and breeding-time detector
Primary Application Mare estrus monitoring and breeding-time assessment
Detection Principle Electrical resistance measurement of vaginal mucus
Measurement Range 0 to 1,000 units
Measurement Resolution 10 units
Probe Length Approximately 43 cm
Display 2.4-inch LCD with LED backlighting
Memory Capacity Up to 250 animals and 200,000 measurements with date and time
Data Transmission USB
Power Supply 4 × 1.5 V AA batteries
Approximate Weight 540 g
Approximate Dimensions 51 × 8 × 19 cm
Recommended Working Temperature 10°C to 45°C
Operating Modes Basic and advanced modes
Configuration Available according to project requirements
Applications Mare Estrus Monitoring: Provides numerical reproductive information to complement behavioral heat detection.

Artificial Insemination Programs: Supports scheduling decisions when determining an appropriate period for insemination.

Natural Breeding Management: Can assist stud farms in planning mating activities and reproductive examinations.

Silent or Weak Estrus: Useful where typical reproductive behavior is difficult to recognize.

Breeding Mare Management: Allows repeated measurements to be recorded as part of individual mare reproductive records.

Veterinary Reproduction Services: Suitable for mobile veterinarians, equine reproductive technicians and breeding consultants.

Research and Teaching: Can be used in veterinary universities and equine reproduction projects studying reproductive cycle changes.
Customization Options Product and accessory configurations can be supplied according to equine breeding project requirements.

Available options may include:
• Mare reproductive monitoring configuration
• Data recording and computer transfer functions
Transport and protective carrying case
• USB data cable
• Replacement batteries
• Reproductive examination accessories
• Multilingual operating documentation
• OEM and distributor packaging
• Configuration according to project requirements
Installation & Maintenance No fixed installation is required. Insert the batteries correctly and verify that the instrument, display and probe are functioning before examination.

Before every measurement, thoroughly clean and disinfect the probe. The mare should be safely restrained and the external reproductive area should be clean before insertion.

Insert the probe carefully without excessive force and maintain a consistent insertion depth between repeated examinations. The electrode section should make appropriate contact with the reproductive tract environment before the measurement cycle is started.

Measurements should be performed regularly at comparable times whenever possible so that reproductive trends can be evaluated more consistently.

After examination, wash and disinfect the probe according to veterinary hygiene procedures. Keep the electronic components and USB connection protected during storage and transport.
Project Cases Mare estrus detectors can be incorporated into reproductive management programs for stud farms, equine breeding centers, artificial insemination stations, veterinary clinics and agricultural research institutions.

In commercial breeding projects, repeated measurements can be combined with estrus behavior, veterinary palpation, ultrasound examination and breeding records to provide a more complete reproductive management workflow.
Product FAQ Q: What does the mare estrus detector measure?
A: It measures changes in the electrical resistance of vaginal mucus and provides numerical data that can support estrus and breeding-time assessment.

Q: Does the detector directly confirm ovulation?
A: It is primarily a reproductive timing aid. For precise ovulation confirmation, results should be combined with veterinary reproductive examination and, where required, ultrasound monitoring.

Q: Why are repeated measurements recommended?
A: Reproductive interpretation is generally more useful when changes are evaluated over several measurements rather than from a single isolated reading.

Q: Can it help with silent estrus?
A: Yes. Electrical resistance measurements can provide an additional objective reference when external estrus signs are weak or atypical.

Q: Can reproductive disease affect readings?
A: Yes. Inflammation or other reproductive tract conditions may influence electrical resistance readings and should be assessed by a veterinarian.

Q: Does the probe require disinfection?
A: Yes. The probe should be thoroughly cleaned and disinfected before and after each examination to support animal health and biosecurity.

Q: Can measurement data be stored?
A: Advanced configurations support storage of individual animal records and measurement results with date and time.

Q: Can data be transferred to a computer?
A: Yes. USB data transfer is available on compatible configurations for reporting, analysis and archiving.
Product Gallery Electronic Mare Estrus Detector

Estrus Detector for Cows and Mares

Large Animal Estrus Detector in Use

Portable Veterinary Estrus Detector

Comments & Inquiries

Leave your questions or requirements below. We will reply as soon as possible.