Global Livestock Equipment Manufacturer & Supplier
SHEWUYOU · Livestock Equipment
Integrated Equipment Solutions for Pig, Cattle & Poultry Farms

24V Transformer Electric Calf Dehorner

Product Showcase Content
Product Name 24V Transformer Electric Calf Dehorner
Product Image 24V transformer electric calf dehorner
Product Overview The 24V Transformer Electric Calf Dehorner is a professional heated dehorning tool designed for controlled horn-bud treatment of young calves in dairy farms, cattle breeding operations and veterinary livestock-management programs.

A safety transformer supplies the handpiece with low-voltage 24V power, while the 250W heating system delivers concentrated heat directly to the stainless-steel burning tip. The heating cartridge is positioned inside the tip area to provide stable heat output and useful thermal reserve during repeated farm use.

The lightweight handpiece, ergonomic grip and long power cable improve operator mobility around calf pens and treatment areas. Interchangeable stainless-steel tips also allow the equipment to be adapted to different calf-management requirements.
Key Features
  • 24V Low-Voltage Operation: Safety transformer supplies the heating handpiece with 24V power for practical use in livestock-farm environments.
  • 250W Heating Output: Provides concentrated thermal performance for professional calf-management applications.
  • Approx. 620°C Maximum Tip Temperature: High operating temperature supports controlled thermal treatment when used according to approved procedures.
  • Integrated Heating Cartridge: Heating element is positioned close to the burning tip for efficient heat transfer and strong thermal reserve.
  • Stainless-Steel Burning Tip: Durable 18 mm reference tip provides corrosion resistance and convenient cleaning.
  • Approx. 11-Minute Heat-Up: Reference configuration reaches operating temperature in approximately 11 minutes.
  • Lightweight Handpiece: Approximate 630 g weight including cable supports comfortable handling during routine farm work.
  • Ergonomic Handle: Shaped grip improves control and operator comfort.
  • 4 m Cable: Long cable provides useful working range around calf pens and treatment facilities.
  • Replaceable Tips: 18 mm and compatible 15 mm stainless-steel tips are available for different requirements.
  • Safe Resting Tray: Stainless-steel holder provides a designated location for the heated handpiece between uses.
Structural Components
  • 24V safety transformer
  • 250W electric heating handpiece
  • Ergonomic insulated handle
  • 15.5 cm stainless-steel heating rod
  • Internal heating cartridge
  • 18 mm stainless-steel burning tip
  • Tip retaining screw
  • 4 m low-voltage connection cable
  • Transformer power cable and plug
  • Stainless-steel resting tray
Working Principle Low-Voltage Power Supply: The safety transformer converts the available mains supply to the 24V operating voltage required by the dehorning handpiece.

Tip Heating: Electrical energy is converted into heat by the internal heating cartridge positioned near the stainless-steel burning tip.

Temperature Stabilization: After the reference heat-up period, the tip reaches the required operating temperature and maintains a useful heat reserve for repeated use.

Controlled Application: The heated ring is used only by trained personnel according to veterinary guidance, manufacturer instructions and applicable animal-welfare regulations.

Safe Resting: Between applications, the hot handpiece should be placed securely on the supplied heat-resistant holder and kept away from animals, combustible materials and unprotected personnel.
Technical Specifications
Product Type Transformer-powered electric calf dehorner
Reference Operating Voltage 24 V
Heating Output 250 W
Maximum Tip Temperature Approx. 620°C
Maximum Heat-Up Time Approx. 11 minutes
Standard Burning Tip 18 mm stainless steel
Optional Burning Tip 15 mm available upon request
Overall Handpiece Length Approx. 30 cm
Heating Rod Length 15.5 cm
Handpiece Weight Approx. 630 g including cable
Cable Length 4 m
Tip Material Stainless steel
Transformer Input & Plug According to destination-market electrical requirements
Applications
  • Dairy calf-rearing operations
  • Beef cattle breeding farms
  • Commercial livestock farms
  • Calf maternity and treatment areas
  • Replacement-heifer facilities
  • Veterinary livestock-management programs
  • Professional calf-care equipment sets
  • Large-scale cattle farm projects
Customization Options
  • 15 mm or 18 mm compatible burning tips
  • Replacement stainless-steel burning tips
  • Replacement 24V / 250W heating rod
  • Transformer input voltage according to destination market
  • Regional plug configuration
  • Cable length according to project requirements
  • Storage and carrying case available upon request
  • Retail or bulk distributor packaging
  • Spare-parts package available upon request
Installation & Maintenance No permanent livestock-building installation is normally required. Position the transformer in a dry, protected working area and connect it only to a compatible electrical supply according to the product instructions and local electrical regulations.

Before each use, inspect the transformer, cable, handle, heating rod and burning tip for damage. Confirm that the tip is correctly secured before energizing the equipment.

Allow sufficient heat-up time and always place the hot handpiece on the supplied heat-resistant holder when it is not being held by the operator. Keep combustible materials away from the heated tip.

Disconnect the equipment from the electrical supply and allow it to cool completely before cleaning, replacing the tip or performing maintenance. Worn or damaged heating components should be replaced with compatible spare parts.

Dehorning should only be performed by appropriately trained personnel under veterinary guidance and in accordance with applicable animal-welfare, restraint, analgesia and anesthesia requirements.
Product FAQ Q: What voltage does the dehorning handpiece use?
A: The reference handpiece operates at 24 V through a safety transformer.

Q: What is the heating output?
A: The reference configuration has a rated output of 250 W.

Q: How hot does the burning tip become?
A: The reference maximum burning-tip temperature is approximately 620°C.

Q: How long does the dehorner take to heat up?
A: Maximum heat-up time is approximately 11 minutes under the referenced operating conditions.

Q: What burning-tip size is supplied?
A: The standard reference configuration includes an 18 mm stainless-steel tip. A compatible 15 mm tip is also available.

Q: Can the burning tip be replaced?
A: Yes. Both the stainless-steel tip and the complete 24V heating rod are available as replaceable components.

Q: Can different mains plugs be supplied?
A: Transformer input and plug configurations can be specified according to destination-market electrical requirements.

Q: Are there animal-welfare requirements for using a calf dehorner?
A: Yes. Operators should follow veterinary guidance and all applicable local requirements regarding calf age, restraint, pain management, anesthesia or analgesia and post-procedure care.
Product Gallery 18mm stainless steel replacement tip for electric calf dehorner

Comments & Inquiries

Leave your questions or requirements below. We will reply as soon as possible.