Global Livestock Equipment Manufacturer & Supplier
SHEWUYOU · Livestock Equipment
Integrated Equipment Solutions for Pig, Cattle & Poultry Farms

4G GSM Remote Alarm System for Livestock Farms

Product Showcase Content
Product Name 4G GSM Remote Alarm System for Livestock Farms
Product Image 4G GSM remote alarm system for livestock farms
Product Overview The 4G GSM Remote Alarm System for Livestock Farms is designed for remote monitoring, alarm notification and basic control of critical livestock-house equipment. It provides cellular communication between farm alarm inputs, environmental sensors, livestock climate controllers and authorized personnel.

When an abnormal condition is detected, the system can transmit SMS alarm information through the cellular network so farm managers can respond even when they are away from the livestock building. Typical monitored conditions include power failure, excessive or insufficient temperature, ventilation faults, controller alarms and other equipment status signals connected through digital or analog inputs.

The system is suitable for commercial poultry houses, pig farms, breeder facilities, livestock groups and agricultural engineering projects where reliable remote alarm communication is required.
Key Features
  • 4G GSM cellular communication for remote livestock farm alarm notification.
  • Automatic SMS transmission when configured alarm conditions are detected.
  • Supports multiple authorized mobile phone numbers for alarm distribution.
  • Suitable for temperature, humidity, equipment status and power failure monitoring.
  • Digital and analog inputs can be connected to compatible sensors, controllers and dry-contact alarm outputs.
  • Remote relay control can be configured for selected auxiliary farm equipment.
  • Rechargeable backup battery configuration helps maintain alarm communication during mains power interruption.
  • Can operate as a stand-alone cellular alarm unit or as part of a livestock-house automation system.
  • Suitable for new livestock house construction and modernization of existing farms.
Structural Components
  • 4G GSM Communication Module: Provides cellular connection for SMS alarm and remote communication functions.
  • External Antenna: Supports cellular signal reception according to the installation environment and network conditions.
  • Digital Input Terminals: Receive dry-contact signals from livestock controllers, power monitors and equipment alarm circuits.
  • Analog Input Terminals: Allow compatible environmental sensors to be connected for alarm monitoring.
  • Output Relays: Provide remote switching capability for compatible external circuits or auxiliary equipment.
  • Communication Interface: Enables integration with compatible livestock climate controllers where required.
  • Backup Battery: Provides temporary power support for alarm notification during mains power interruption.
  • Protective Enclosure: Houses the electronic components and terminal connections for organized installation in farm control areas.
Working Principle / Structural Principle The remote alarm unit continuously monitors connected digital inputs, analog sensors and communication signals. Each input can be assigned to a defined livestock-house alarm condition, such as high temperature, low temperature, ventilation failure, controller alarm or mains power loss.

When the status of a monitored input reaches the configured alarm condition, the controller processes the event and sends an SMS notification through the 4G GSM cellular network to authorized farm personnel. Depending on the selected configuration, users may also request operating information or control designated relay outputs remotely.

A rechargeable backup battery can maintain the alarm electronics for a limited period during a power interruption, allowing the system to issue a power failure warning even when the primary electrical supply is unavailable.
Technical Specifications
Product Type 4G GSM cellular livestock farm alarm and information system
Communication 4G GSM cellular network
Alarm Notification SMS notification to authorized mobile phones
Mobile Phone Recipients Customizable; reference configuration supports up to 9 mobile phone numbers
Digital Inputs Customizable; reference configuration supports 8 digital inputs
Analog Inputs Customizable; reference configuration supports 2 analog inputs
Relay Outputs Customizable; reference configuration supports 4 remotely controllable relays
Environmental Sensors Temperature and humidity monitoring options available upon request
Controller Communication Available according to compatible controller interface; RS422 configuration available for applicable systems
Power Failure Alarm Available as part of the alarm configuration
Backup Power Rechargeable backup battery configuration available
Power Supply According to project requirements
SIM Card / Network According to local cellular operator and regional network requirements
Installation Control room, electrical room or protected livestock-house service area
Applications
  • Commercial broiler houses
  • Layer and breeder poultry houses
  • Farrowing, nursery, finishing and breeding pig houses
  • Livestock climate-control systems
  • Power failure monitoring systems
  • Ventilation and environmental alarm systems
  • Farm electrical and equipment rooms
  • Centralized livestock farm monitoring projects
  • Remote agricultural facilities where operators are not continuously on site
Customization Options The alarm system can be configured according to the livestock house layout, existing controller platform, regional communication network and project alarm strategy.
  • Number and type of alarm inputs: customizable
  • Analog sensor configuration: customizable
  • Temperature and humidity sensor options: available upon request
  • Remote relay control functions: according to project requirements
  • Alarm message descriptions: customizable for individual houses or equipment
  • Controller communication interface: according to project requirements
  • Power supply configuration: customizable
  • Backup battery capacity: available according to project requirements
  • Antenna and installation arrangement: designed according to local cellular coverage and farm conditions
  • Integration with audible and visual alarm devices: available upon request
Installation & Maintenance Install the 4G GSM alarm controller in a dry, accessible and protected location such as a livestock-house control room or electrical equipment area. The antenna should be positioned where reliable cellular signal reception can be achieved.

Connect the digital inputs to the designated dry-contact alarm outputs of livestock climate controllers, power monitoring relays or other compatible equipment. Analog sensors and communication interfaces should be connected according to the selected system configuration and electrical wiring diagram.

After installation, insert and configure the appropriate SIM card, register authorized phone numbers, define alarm messages and test every alarm input individually. A complete commissioning test should include power failure notification, sensor alarms, communication quality and remote relay operation where applicable.

Routine maintenance should include checking cellular signal quality, terminal connections, antenna condition, alarm functions and backup battery status. Periodic test alarms are recommended as part of the livestock farm preventive maintenance program.
Project Cases Commercial Poultry House Remote Alarm Project
A GSM alarm controller can receive alarm contacts from the poultry climate controller and monitor power supply and environmental conditions. When an abnormal event occurs, designated farm managers receive SMS notifications and can take action without being continuously present in the poultry house.

Multi-House Pig Farm Alarm Upgrade
Individual alarm inputs can be assigned to different pig houses, ventilation controllers or equipment zones. Alarm messages can identify the corresponding building or equipment circuit, helping maintenance personnel locate the alarm source more quickly.

Remote Farm Power Failure Monitoring
With backup battery support, the GSM alarm system can detect loss of mains electricity and transmit a cellular warning to farm personnel, improving response time for generator startup or emergency inspection.
Product FAQ Q1: What alarms can the 4G GSM system send?
A: Depending on the connected inputs and sensors, it can be configured for power failure, high or low temperature, humidity deviation, ventilation fault, controller alarm and other equipment status alarms.

Q2: Can several people receive the same alarm?
A: Yes. Multiple authorized mobile phone numbers can be configured. The exact number can be customized according to the selected controller and project requirements.

Q3: Can it continue sending alarms after a power failure?
A: A rechargeable backup battery configuration can support the alarm controller during a mains power interruption, allowing power failure notifications to be transmitted subject to battery condition and cellular network availability.

Q4: Can temperature and humidity sensors be connected directly?
A: Compatible sensor inputs can be provided. The reference system supports temperature and humidity monitoring, while final sensor type and quantity should be confirmed according to the project.

Q5: Can the system remotely control equipment?
A: Remote relay control can be configured for compatible circuits. The connected load and control logic should be designed through suitable relays, contactors or control interfaces.

Q6: Can it connect to an existing poultry or pig house controller?
A: Yes, where the existing controller provides compatible dry-contact alarm outputs or supported communication interfaces. Wiring and protocol compatibility should be confirmed before production.

Q7: Does the system require internet access?
A: Basic GSM alarm functions can operate through the cellular network. Additional internet or data functions depend on the selected communication configuration and local network service.

Q8: Can it be supplied for different countries?
A: Yes. Cellular module, SIM arrangement, power supply and installation configuration can be selected according to local network standards and project requirements.
Product Gallery 4G GSM cellular livestock farm alarm controller

livestock farm wireless communication alarm equipment

poultry house climate controller with remote alarm integration

Comments & Inquiries

Leave your questions or requirements below. We will reply as soon as possible.