| Product Name | Portable Water EC/TDS Meter |
| Product Image | ![]() |
| Product Overview | The Portable Water EC/TDS Meter is a handheld low-range water quality instrument for measuring electrical conductivity (EC), total dissolved solids (TDS) and temperature. Its compact construction and separate probe make it practical for field testing at livestock farms, agricultural water systems and engineering sites. The meter is particularly suitable for low ionic-strength water applications. In commercial pig farms, it can be used for comparative inspection of source water, treated water, storage tanks and livestock drinking-water distribution points. The rugged housing and portable probe configuration also support routine maintenance and commissioning work. |
| Key Features | • Low-range EC measurement from 0 to 3999 μS/cm. • TDS measurement from 0 to 2000 ppm. • Integrated temperature measurement with automatic temperature compensation. • Rugged IP67-rated meter housing for demanding field environments. • Replaceable EC/TDS probe for easier long-term service. • Two-ring conductivity probe designed for low-range EC and TDS testing. • Quick-connect DIN probe connection for convenient installation and removal. • Multi-level LCD display provides EC/TDS and temperature information. • Automatic one-point EC/TDS calibration simplifies routine testing. • Selectable TDS conversion factor supports different testing requirements. • Low-battery indication and configurable automatic shut-off support field operation. |
| Structural Components | The instrument consists of a rugged handheld meter body, LCD display, operating buttons, battery compartment, external EC/TDS probe and connecting cable. The supplied probe combines EC/TDS sensing with a built-in temperature sensor. The two-ring conductivity design is intended for low-range measurements, while the replaceable probe structure facilitates servicing and component replacement. A Quick Connect DIN interface provides a secure connection between the meter and probe. The cable connection is designed for convenient attachment and removal during inspection, transportation and maintenance. |
| Working Principle / Structural Principle | EC measurement is based on the electrical conductivity of the water sample. The conductivity probe detects the electrical response of the solution and the meter converts this response into an EC reading. TDS is derived from the measured conductivity using a selectable conversion factor. The conversion factor can be adjusted according to the characteristics of the water and the testing application. The integrated temperature sensor measures sample temperature while the meter automatically compensates EC/TDS readings for temperature effects. This helps provide more consistent measurements when water temperature varies. |
| Technical Specifications | Measurement Parameters: EC, TDS and Temperature EC Range: 0 to 3999 μS/cm EC Resolution: 1 μS/cm EC Accuracy: ±2% F.S. at 25°C / 77°F EC Calibration: Automatic, one point at 1413 μS/cm TDS Range: 0 to 2000 ppm TDS Resolution: 1 ppm (mg/L) TDS Accuracy: ±2% F.S. at 25°C / 77°F TDS Conversion Factor: Selectable from 0.45 to 1.00 TDS Calibration: Automatic one-point calibration according to the selected conversion factor Temperature Range: -5.0 to 105.0°C / 23.0 to 221.0°F Temperature Resolution: 0.1°C / 0.1°F Temperature Accuracy: ±0.5°C / ±1.0°F at 25°C / 77°F Temperature Compensation: Automatic, selectable from 0.0 to 2.4%/°C Probe: EC/TDS/temperature sensor with Quick Connect DIN connection and 1 m cable Meter Protection: IP67 Power Supply: 3 × 1.5 V AAA batteries Continuous Operation: Approximately 500 hours Auto Shut-Off: Selectable at 8 minutes or 60 minutes, or disabled Operating Environment: 0 to 50°C / 32 to 122°F, maximum relative humidity 100% Meter Dimensions: Approximately 155 × 63 × 30 mm Weight: Approximately 197 g with batteries Final product configuration, accessories and project-specific specifications are available upon request. |
| Applications | • Commercial pig farms and integrated livestock production facilities • Livestock drinking-water quality inspection • Poultry and animal breeding facilities • Farm water treatment and filtration systems • Reverse osmosis and purified-water systems • Agricultural water supply and irrigation systems • Water storage tanks and distribution networks • Drinking-line commissioning and maintenance • Pig farm construction and facility engineering projects • Agricultural contractors, livestock equipment distributors and service teams |
| Customization Options | SHEWUYOU can support livestock groups, agricultural engineering companies, farm contractors, distributors and project procurement teams with application-oriented water testing solutions. Available options include: • Product configuration according to project requirements • Replacement EC/TDS probes for long-term maintenance • Calibration solutions and testing accessories available upon request • Spare-part packages for commercial livestock projects • Distributor and agency supply arrangements • Solutions designed according to local climate and farm conditions • Bulk procurement configurations for multi-house or multi-farm projects |
| Installation & Maintenance | No fixed installation is required. Connect the probe through the DIN interface, rinse the sensing end and immerse the probe into a representative water sample. Keep the sensing area sufficiently clear of the container wall and bottom during measurement. Before routine operation, calibrate the EC/TDS function with a suitable conductivity standard according to the selected testing range. Allow the reading to stabilize before recording results. Rinse the probe with clean or deionized water between samples to minimize cross-contamination. Keep the sensing area clean and inspect the cable and connector regularly. Replace the electrode when its measurement performance no longer meets project requirements. Store the meter and probe according to the applicable manufacturer's maintenance instructions and protect the equipment from unnecessary mechanical impact during transportation. |
| Project Cases | The meter can be incorporated into water quality inspection procedures for commercial pig farm construction, livestock facility upgrades and agricultural water system commissioning. Typical project deployment includes comparative testing at groundwater or municipal supply points, water treatment outlets, storage tanks, building inlets and livestock drinking-line endpoints. This provides engineering teams with practical EC and TDS data during commissioning and routine maintenance. For multi-house livestock facilities and integrated farming projects, multiple meters, replacement probes and calibration accessories can be supplied according to project requirements. |
| Product FAQ | Q: What does the Portable Water EC/TDS Meter measure? A: It measures electrical conductivity, total dissolved solids and temperature. Q: Is this model designed for low-range water testing? A: Yes. The referenced configuration provides EC measurement from 0 to 3999 μS/cm and TDS measurement from 0 to 2000 ppm. Q: Can it be used for livestock drinking water? A: Yes. It can be used for routine comparative testing of water sources, treatment systems, storage tanks and livestock drinking-water distribution points. Q: What is the purpose of temperature compensation? A: Water conductivity changes with temperature. Automatic temperature compensation adjusts the EC/TDS measurement to reduce the influence of sample temperature variation. Q: Is the probe replaceable? A: Yes. The EC/TDS/temperature probe is designed as a replaceable component for easier long-term maintenance. Q: Does the meter require permanent installation? A: No. It is a portable handheld instrument intended for field measurement and routine water quality inspection. Q: Can additional probes and accessories be supplied? A: Yes. Replacement probes, calibration solutions and related accessories are available upon request and according to project requirements. |
| Product Gallery | ![]() ![]() ![]() |




Comments & Inquiries
Leave your questions or requirements below. We will reply as soon as possible.