Global Livestock Equipment Manufacturer & Supplier
SHEWUYOU · Livestock Equipment
Integrated Equipment Solutions for Pig, Cattle & Poultry Farms

Veterinary Clinical Micro Centrifuge

Product Name Veterinary Clinical Micro Centrifuge
Product Image veterinary clinical micro centrifuge
Product Overview The Veterinary Clinical Micro Centrifuge is a compact, multipurpose benchtop centrifugation solution developed for routine animal health and veterinary laboratory workflows. Its small footprint makes it practical for clinical workstations, commercial livestock laboratories, farm-based diagnostic rooms and centralized animal health facilities.

The centrifuge is designed to process blood, urine, fecal and microhematocrit specimens in one unit. A fixed-angle rotor, dedicated tube carriers and simple preset controls provide a straightforward workflow for common veterinary sample preparation procedures.

For commercial pig farms and integrated livestock production systems, the equipment can be incorporated into on-site or centralized veterinary laboratories for herd health monitoring, sample preparation and routine diagnostic testing. Configuration and accessories can be supplied According to project requirements.
Key Features
  • Compact benchtop design for veterinary clinical and livestock laboratory environments.
  • Processes blood, urine, fecal and microhematocrit specimens in one centrifuge.
  • Fixed-angle rotor remains at a controlled angle during sample processing.
  • Simple two-button operating interface supports straightforward routine operation.
  • Three preset cycles are provided for common veterinary centrifugation procedures.
  • Preset cycles can be customized for validated laboratory workflows where applicable.
  • Clear safety lid supports sample observation and visual monitoring during operation.
  • Reinforced guard bowl provides an additional structural safety barrier around the rotor.
  • High-power brushless motor is designed for long-term operation with no routine motor maintenance.
  • Lid safety system prevents operation when the lid is not correctly closed and latched.
  • Compact footprint helps maximize available laboratory bench space.
  • Rotor carriers and adapters support multiple veterinary tube formats.
Structural Components The Veterinary Clinical Micro Centrifuge incorporates a compact external housing, centrifuge chamber, fixed-angle rotor assembly, tube carriers, sample adapters, reinforced guard bowl, transparent safety lid and control interface.

The referenced configuration includes dedicated carriers for different tube lengths and sample formats, together with microhematocrit adapters. The supplied rotor and tube holders are designed as an integrated operating package rather than requiring separate basic accessories.

Typical structural elements include:
  • Compact benchtop housing
  • Fixed-angle rotor assembly
  • Sample tube carriers
  • Microhematocrit adapters
  • Reinforced rotor guard bowl
  • Clear impact-resistant safety lid
  • Mechanical lid-latching mechanism
  • Two-button control interface
  • LED cycle-status indication
  • Brushless motor drive
Exact rotor configuration, carrier combination and accessory package are Customizable and Available upon request.
Working Principle / Structural Principle The centrifuge separates components of biological samples according to density by applying centripetal acceleration. Sample tubes are positioned in the rotor using compatible carriers or adapters and balanced before the centrifugation cycle begins.

During rotation, denser particles move toward the bottom or outer region of the sample tube while lighter components remain closer to the center. This density-based separation can prepare specimens for subsequent veterinary clinical examination or laboratory analysis.

The fixed-angle rotor maintains the samples at a defined angle during processing. Preset cycles provide commonly used time and speed combinations, while validated laboratory procedures may use customized cycle settings where supported.

For microhematocrit testing, compatible capillary tubes can be processed using the dedicated adapter, allowing packed cell volume-related sample preparation according to the applicable veterinary laboratory procedure.
Technical Specifications
Equipment Type Compact veterinary clinical centrifuge
Rotor Type Fixed-angle rotor
Maximum Speed Up to 3,900 RPM
Maximum RCF Up to 1,850 × g
Standard Capacity 6 samples up to 2 mL; 6 samples up to 15 mL; 8 microhematocrit tubes up to 75 mm
Configurable Microhematocrit Capacity Up to 24 microhematocrit tubes up to 75 mm with additional adapters
Tube Compatibility Up to 16 × 100 mm or 10 mL; up to 16 × 125 mm or 15 mL; microhematocrit tubes up to 75 mm
Preset Cycle 1 10 minutes / 3,900 RPM / 1,650 × g
Preset Cycle 2 5 minutes / 2,000 RPM / 500 × g
Preset Cycle 3 6 minutes / 3,800 RPM / 1,550 × g
Timer Range 1 to 30 minutes
Dimensions 12 × 14 × 9 in (30.5 × 35.6 × 22.9 cm)
Weight 12 lb (5.4 kg)
Power Supply 100–240 VAC, 50/60 Hz
Sound Level Approximately 64 dBA
Warranty 2-year standard warranty for the referenced configuration
Project Configuration Customizable / According to project requirements / Available upon request
Applications
  • Veterinary blood chemistry sample preparation
  • Serum and plasma sample processing
  • Urine sample preparation
  • Fecal sample processing
  • Microhematocrit and packed cell volume workflows
  • Animal health diagnostic laboratories
  • Commercial pig farm laboratories
  • Livestock breeding and production facilities
  • Veterinary clinics and animal health centers
  • Centralized livestock diagnostic laboratories
  • Veterinary research and laboratory testing facilities
The equipment is particularly suitable for commercial livestock operations that require routine sample processing close to the herd health or diagnostic workstation. It can also be deployed as part of a centralized laboratory serving multiple farms or production sites.
Customization Options For international B2B procurement, the Veterinary Clinical Micro Centrifuge can be configured around sample types, tube formats, laboratory throughput and local electrical requirements.

Possible project considerations include rotor and carrier configuration, microhematocrit adapters, tube capacity, preset cycles, control configuration, voltage version, packaging and accessory combinations.

For commercial pig farms, livestock groups and agricultural engineering contractors, centrifuge specifications can be coordinated with veterinary laboratory layout, laboratory benching, electrical services, sample-flow planning and biosecurity zoning.

Equipment configuration is Customizable, According to project requirements, and Available upon request.
Installation & Maintenance The centrifuge is designed for simple benchtop installation and does not require permanent mechanical installation. Position it on a stable, level laboratory surface with sufficient clearance for ventilation, lid operation and routine cleaning.

Before each run, verify correct rotor and carrier installation and ensure that tubes are loaded symmetrically and balanced. Use only approved tube sizes and adapters, and operate within the specified speed and capacity limits.

The clear lid and lid safety system provide controlled access to the rotor chamber. The centrifuge should not be opened until the rotor has completely stopped.

Routine maintenance includes inspection and cleaning of the rotor, tube carriers, adapters, guard bowl and lid. For the referenced configuration, the manufacturer recommends calibration every two years.

For cleaning and disinfection, the referenced manufacturer specifies isopropyl alcohol, soap and water, or a 10% bleach solution. The equipment should be unplugged before cleaning and all surfaces dried immediately afterward. Chemical compatibility requirements should always be observed.
Project Cases The Veterinary Clinical Micro Centrifuge is suitable for international procurement programs involving commercial pig farms, integrated livestock production groups, veterinary clinics, animal health laboratories, diagnostic service providers and agricultural engineering contractors.

For a commercial swine production complex, the centrifuge can be installed within a dedicated herd health laboratory to support routine blood, urine, fecal and microhematocrit sample preparation. Multiple units may be allocated to separate sample-processing workstations according to laboratory workflow.

For centralized livestock diagnostic centers, compact centrifuges can be integrated with sample reception, preparation, molecular testing and clinical analysis areas. Equipment quantities, accessory packages and electrical configurations are Available upon request.

For new farm construction projects, laboratory equipment planning can be coordinated with laboratory bench layout, electrical infrastructure, ventilation, drainage, sample flow and biosecurity zoning.
Product FAQ

Q: What is the Veterinary Clinical Micro Centrifuge used for?
A: It is designed for routine veterinary centrifugation of blood, urine, fecal and microhematocrit specimens.

Q: Is it suitable for commercial pig farms?
A: Yes. Its compact benchtop format is suitable for on-site farm laboratories, herd health rooms and centralized diagnostic facilities serving commercial livestock operations.

Q: What is the maximum operating speed?
A: The referenced configuration provides a maximum speed of 3,900 RPM and a maximum RCF of 1,850 × g.

Q: What sample tubes can it accommodate?
A: The referenced configuration supports tubes up to 16 × 100 mm or 10 mL, tubes up to 16 × 125 mm or 15 mL, and microhematocrit tubes up to 75 mm.

Q: How many samples can be processed at one time?
A: The standard configuration accommodates 6 samples up to 2 mL, 6 samples up to 15 mL, or 8 microhematocrit tubes up to 75 mm. Microhematocrit capacity can be configured up to 24 with additional adapters.

Q: Does the centrifuge require complicated installation?
A: No. It is designed for stable benchtop placement and requires an appropriate electrical supply, level working surface and sufficient operating clearance.

Q: Can the preset cycles be customized?
A: The referenced product documentation states that cycle settings can be customized where required for validated laboratory procedures.

Q: Can the configuration be adapted for a livestock engineering project?
A: Yes. Rotor configuration, adapters, capacity, electrical requirements, accessories and procurement quantities are Customizable and can be supplied According to project requirements.

Product Gallery
veterinary clinical micro centrifuge product view
compact veterinary centrifuge for animal health laboratory
veterinary blood urine fecal centrifuge
commercial livestock veterinary laboratory centrifuge

Comments & Inquiries

Leave your questions or requirements below. We will reply as soon as possible.