| Product Name | Veterinary Mini Centrifuge | ||||||||||||||||||||||||
| Product Image | ![]() |
||||||||||||||||||||||||
| Product Overview | The Veterinary Mini Centrifuge is a compact benchtop sample-processing unit designed for routine veterinary laboratory applications. Its space-efficient construction makes it suitable for animal clinics, farm laboratories, livestock diagnostic centers and decentralized testing areas where bench space is limited. The centrifuge can support processing of blood, urine, fecal and microhematocrit samples through dedicated holders, adapters and rotor configurations. A compact fixed-angle design provides a practical solution for routine sample separation while allowing different tube formats to be accommodated within the applicable configuration. For commercial livestock projects, the equipment can be integrated into veterinary laboratory workflows supporting herd health monitoring, sample preparation and routine diagnostic testing. Configuration, electrical specification and accessories can be supplied According to project requirements. |
||||||||||||||||||||||||
| Key Features |
|
||||||||||||||||||||||||
| Structural Components | The veterinary centrifuge consists of a compact outer housing, centrifuge chamber, fixed-angle rotor, tube carriers or adapters, safety lid and control interface. The rotor and sample holders are selected according to the required tube dimensions and veterinary application. Typical component configuration may include:
|
||||||||||||||||||||||||
| Working Principle / Structural Principle | The Veterinary Mini Centrifuge separates components of liquid or prepared biological samples by centrifugal force. Sample tubes are positioned symmetrically in the rotor using compatible carriers or adapters. When the rotor reaches the selected operating speed, centrifugal force causes components with different densities to separate. For veterinary blood samples, centrifugation can be used to assist serum or plasma preparation. Urine samples can be concentrated for sediment examination, while fecal preparations can be processed for applicable flotation or concentration procedures. Microhematocrit tubes can be centrifuged for packed cell volume assessment. The fixed-angle rotor maintains the sample tubes at a defined angle during operation. Correct balancing, compatible tube loading and appropriate speed/time settings should always follow the applicable laboratory procedure and equipment instructions. |
||||||||||||||||||||||||
| Technical Specifications |
|
||||||||||||||||||||||||
| Applications |
|
||||||||||||||||||||||||
| Customization Options | For international B2B procurement, the Veterinary Mini Centrifuge can be specified around the laboratory workflow, sample types, tube formats, electrical supply and project volume. Possible configuration considerations include rotor type, tube capacity, microhematocrit adapters, sample carriers, control interface, preset programs, voltage requirements, packaging and accessory combinations. For livestock engineering projects and commercial pig farm laboratory construction, equipment specifications can be coordinated with laboratory bench layout, electrical infrastructure, sample-processing zones and biosecurity requirements. Configuration is Customizable, According to project requirements, and Available upon request. |
||||||||||||||||||||||||
| Installation & Maintenance | The Veterinary Mini Centrifuge is designed for straightforward benchtop installation. Position the unit on a stable, level laboratory work surface with sufficient clearance around the equipment for ventilation, loading and routine cleaning. Before operation, verify that the rotor and tube holders are correctly installed and that sample tubes are balanced according to the applicable operating procedure. Do not exceed the rated rotor speed, tube dimensions or capacity. Routine maintenance should include inspection of the rotor, tube carriers, adapters, safety lid and chamber. Remove spills promptly and clean the chamber and external surfaces using cleaning agents approved for the specific equipment. For the referenced TrueBond configuration, the manufacturer recommends centrifuge calibration every two years. Cleaning and disinfection should follow the manufacturer's approved procedures and chemical compatibility requirements. |
||||||||||||||||||||||||
| Project Cases | The Veterinary Mini Centrifuge is suitable for international procurement programs involving commercial pig farms, livestock breeding groups, veterinary clinics, animal health laboratories, diagnostic service providers and agricultural project contractors. For centralized livestock diagnostic facilities, compact centrifuges can be installed at sample preparation stations alongside pipetting equipment, analyzers and other veterinary laboratory instruments. Their small footprint is particularly useful where laboratory bench space must be efficiently allocated. For new livestock facility construction and farm engineering projects, equipment specifications can be planned together with laboratory layout, electrical services, work benches, sample flow and biosecurity zoning. Bulk procurement and project-specific equipment schedules are Available upon request. |
||||||||||||||||||||||||
| Product FAQ |
Q: What samples can a veterinary mini centrifuge process? Q: Is the centrifuge suitable for commercial pig farms? Q: What is the maximum speed of the referenced configuration? Q: What tube sizes are supported? Q: Does the centrifuge require special installation? Q: How should the centrifuge be maintained? Q: Can the centrifuge be configured for a specific agricultural project? |
||||||||||||||||||||||||
| Product Gallery |
![]() ![]() ![]() ![]() |




Comments & Inquiries
Leave your questions or requirements below. We will reply as soon as possible.