| Product Name | 10-Stage Poultry House Temperature and Ventilation Controller | ||||||||||||||||||||||||||||
| Product Image | ![]() |
||||||||||||||||||||||||||||
| Product Overview | The 10-Stage Poultry House Temperature and Ventilation Controller is designed for automatic environmental management in commercial broiler, breeder and layer houses. It coordinates heating, staged fan ventilation, cooling equipment, air inlets or tunnel curtains and alarm functions according to programmed climate settings. The controller is particularly suitable for tunnel-ventilated poultry buildings where environmental conditions must change progressively as bird age, body weight, heat production and outside climate conditions vary. By linking temperature sensing with staged equipment operation, the controller helps maintain a more stable poultry-house environment while reducing unnecessary manual adjustment. The system can be incorporated into new poultry-house construction, steel-structure livestock buildings and renovation projects. Sensor configuration, output allocation and connected ventilation equipment can be adapted according to project requirements. |
||||||||||||||||||||||||||||
| Key Features |
|
||||||||||||||||||||||||||||
| Structural Components |
|
||||||||||||||||||||||||||||
| Working Principle / Structural Principle | Environmental sensors continuously send poultry-house climate information to the controller. The controller compares actual conditions with programmed temperature, ventilation and humidity targets and then activates the corresponding control stage. During cool conditions, the controller can operate heating equipment and minimum-ventilation fans to maintain temperature while removing moisture and stale air. As indoor temperature rises, additional fan stages are activated progressively. In tunnel-ventilated houses, higher stages can operate tunnel fans together with tunnel inlets or cooling curtains. Where static-pressure control is incorporated, inlet or curtain position can be coordinated with ventilation demand to maintain suitable air distribution. Cooling equipment can also be programmed to operate at designated stages, while humidity-related logic can limit cooling or increase ventilation when required. This staged operating principle helps avoid sudden changes in airflow and provides a structured transition between heating, minimum ventilation, cooling and full tunnel ventilation. |
||||||||||||||||||||||||||||
| Technical Specifications |
|
||||||||||||||||||||||||||||
| Applications |
|
||||||||||||||||||||||||||||
| Customization Options | The controller and associated poultry-house climate system can be configured according to project requirements. Available customization may include:
|
||||||||||||||||||||||||||||
| Installation & Maintenance | The controller should normally be mounted in a convenient service area of the poultry house where operators can access the display while minimizing direct exposure to water, dust accumulation and corrosive contaminants. Temperature sensors should be positioned within the representative bird-occupied zone and away from direct heater discharge, cooling-pad airflow, doors or other locations that could distort temperature readings. Humidity and static-pressure sensors should be installed according to the ventilation-system design. Fan motors, heaters and other higher-current loads should be connected through correctly sized contactors, circuit protection and electrical panels when required. Wiring should be separated between low-voltage sensor circuits and power cables wherever practical. Routine maintenance includes checking sensor accuracy, inspecting terminals, confirming fan and curtain operation, cleaning the controller enclosure, testing alarm functions and reviewing programmed ventilation stages before each new flock cycle. |
||||||||||||||||||||||||||||
| Project Cases | Commercial Broiler House: The controller can manage minimum ventilation during early flock stages, increase fan capacity progressively as heat load rises, and switch to tunnel ventilation and evaporative cooling during hot-weather operation. Breeder House: Heating, ventilation, inlet positioning and alarm functions can be coordinated to maintain more stable environmental conditions through different production stages. Layer House Renovation: Existing fans, tunnel inlets, cooling pads and environmental sensors can be integrated into a staged control strategy after electrical compatibility and equipment requirements are confirmed. Final controller programming and equipment allocation should be designed according to house dimensions, stocking density, ventilation capacity and local climate conditions. |
||||||||||||||||||||||||||||
| Product FAQ | Q1: What does a 10-stage poultry climate controller control? It can coordinate multiple operating stages for fans, heating, cooling, air inlets or tunnel curtains and alarms. The exact output allocation depends on the selected program and project configuration. Q2: Can it be used in tunnel-ventilated poultry houses? Yes. This type of controller is particularly suitable for staged and tunnel-ventilation systems used in commercial poultry production. Q3: Can temperature and humidity sensors be connected? Yes. Compatible temperature and humidity sensors can be integrated according to the selected controller configuration. Q4: Can the controller operate air inlets or cooling curtains? Yes. Inlet or curtain functions can be linked with selected fan stages or, where supported by the system design, static-pressure feedback. Q5: Does it support minimum ventilation? Yes. Minimum ventilation can be programmed as part of the poultry-house environmental control strategy and can transition progressively to higher ventilation stages. Q6: Can it control evaporative cooling? Yes. Cooling equipment can be assigned to an operating stage according to temperature, humidity and project requirements. Q7: Is remote management available? Remote monitoring or centralized control can be provided when the controller is combined with a compatible communication gateway or farm-management system. Q8: Can the control logic be customized for different countries? Yes. Ventilation stages, temperature curves and equipment allocation can be designed according to local climate and farm conditions. |
||||||||||||||||||||||||||||
| Product Gallery | ![]() ![]() ![]() ![]() |