Dairy Cow Subclinical Mastitis Detector

Product Showcase content
Product Name Dairy Cow Subclinical Mastitis Detector
Product Image Dairy Cow Subclinical Mastitis Detector with LCD Display and Milk Sampling Cup
Product Overview The Dairy Cow Subclinical Mastitis Detector is a portable electronic screening instrument designed for rapid quarter-by-quarter evaluation of udder health on dairy farms.

The integrated sampling cup contains measuring electrodes that detect changes in the electrical properties of milk. Test results are shown directly on the LCD screen, allowing farm personnel to compare readings from the four udder quarters.

Its handheld design, replaceable 9V battery and low power consumption make it suitable for routine mastitis monitoring in milking parlors, dairy barns and veterinary service operations.
Product Gallery Product gallery views can include the complete handheld detector, milk sampling cup, measuring electrodes, LCD display, waterproof-style switch, replaceable battery compartment, protective carrying case and dairy farm testing applications.
Key Features
  • Portable electronic screening for subclinical mastitis risk.
  • Rapid quarter-by-quarter milk testing.
  • Integrated sampling cup with measuring electrodes.
  • Large LCD digital display for direct reading.
  • Low power consumption of approximately 12 mA.
  • Replaceable 9V standard or alkaline battery.
  • Low-battery warning shown as LB on the display.
  • Water-resistant design suitable for dairy farm environments.
  • No chemical reagent is required for routine measurement.
Working Principle Mastitis can change the concentration of electrolytes such as sodium and chloride in milk. These changes affect the electrical conductivity and resistance characteristics of the milk sample.

The detector measures these electrical characteristics through electrodes in the sampling cup and converts the measurement into a numerical reading on the LCD screen.

Results should be evaluated together with differences between the four quarters and the cow's previous readings. The instrument is intended as a screening aid rather than a definitive laboratory diagnosis.
Technical Specifications
  • Product Name: Dairy Cow Subclinical Mastitis Detector
  • Product Type: Electronic Milk Mastitis Screening Instrument
  • Detection Method: Electrical Property Measurement of Milk
  • Display: LCD 3.5-Character Digital Display
  • Minimum Display Unit: 10 Units
  • Power Supply: 9V Standard or Alkaline Battery
  • Power Consumption: Approximately 12 mA
  • Low-Battery Indicator: LB
  • Overall Dimensions: Approximately 36 × 20 × 15 cm
  • Product Weight: Approximately 0.9 kg
  • Sampling Method: Direct Milk Sampling into Integrated Cup
  • Animal Application: Dairy Cows
  • Primary Application: Subclinical Mastitis Risk Screening

Reference interpretation for this model: readings above 300 units generally indicate lower mastitis risk; readings between 250 and 300 units require closer monitoring; readings below 250 units indicate increased abnormality risk. Results should also be compared between quarters and interpreted together with herd history and veterinary assessment.

Applications
  • Routine subclinical mastitis screening.
  • Quarter-by-quarter dairy cow udder monitoring.
  • Pre-milking or herd health inspection programs.
  • Monitoring cows with previously abnormal readings.
  • Dairy farm mastitis-control programs.
  • Milking parlors and dairy breeding farms.
  • Veterinary and herd-health service applications.
Installation & Maintenance Use and Maintenance:
  • Install a suitable 9V battery before operation.
  • Ensure the sampling cup and measuring electrodes are clean before testing.
  • Use milk from each udder quarter separately for comparative evaluation.
  • Fill the sampling cup to at least the indicated measurement level.
  • Rinse the sampling cup thoroughly after completing the test.
  • Clean the cup carefully after an abnormal sample to reduce carryover between cows.
  • Do not use abrasive tools that could damage the measuring electrodes.
  • Replace the battery when the LB warning appears.
  • Store the detector clean and dry in its protective case.
Product FAQ

Q: What is this mastitis detector used for?
A: It is designed for rapid screening of subclinical mastitis risk by testing milk from individual udder quarters.

Q: Does it directly measure somatic cell count?
A: No. It measures changes in the electrical properties of milk that can be associated with udder inflammation.

Q: How are the readings interpreted?
A: For this model, readings above 300 units generally indicate lower risk, 250–300 units suggest closer monitoring, and readings below 250 units indicate increased abnormality risk.

Q: Should all four quarters be tested?
A: Yes. Comparing readings from all four quarters provides more useful information than relying on a single measurement.

Q: What type of battery does the detector use?
A: It uses one 9V standard or alkaline battery.

Q: Does the instrument require chemical reagents?
A: No. Routine measurement is electronic and does not require a test reagent.

Q: Is one abnormal reading enough to diagnose mastitis?
A: No. Readings should be compared with the other quarters, previous measurements and clinical observations, with laboratory or veterinary confirmation when necessary.

Q: How should the sampling cup be cleaned?
A: Rinse the cup and electrodes thoroughly with clean water after testing and remove all residual milk before the next measurement.