Global Livestock Equipment Manufacturer & Supplier
SHEWUYOU · Livestock Equipment
Integrated Equipment Solutions for Pig, Cattle & Poultry Farms

Temperature & Humidity Data Logger

Product Showcase Content
Product Name ELITECH GSP-6 TEMPERATURE & HUMIDITY DATA LOGGER
Product Image Elitech GSP-6 Temperature and Humidity Data Logger
Product Overview The Elitech GSP-6 Temperature & Humidity Data Logger is a professional environmental monitoring instrument designed for continuous temperature and relative humidity recording. It combines external sensors, a large LCD display, programmable logging intervals, audible and visual alarms, and USB data management in one compact unit.

The GSP-6 is suitable for livestock farms, veterinary vaccine storage, laboratories, cold rooms, refrigerators, feed storage areas and other temperature-sensitive environments. Recorded data can be reviewed, analyzed and exported for environmental control, traceability and quality management.
Product Gallery GSP-6 data logger main unit, large LCD display, external temperature probe, temperature-humidity combined probe, USB interface and optional buffered vaccine temperature probe.
Key Features
  • Temperature & Humidity Monitoring: Continuously records environmental temperature and relative humidity.
  • Wide Temperature Range: Supports measurements from -40°C to +85°C.
  • 10–99% RH Range: Suitable for routine humidity monitoring in storage and farm environments.
  • 16,000 Record Capacity: Stores long-term environmental data for later analysis.
  • 2.8-Inch LCD: Large display allows convenient viewing of temperature, humidity and logging status.
  • Audible and Visual Alarm: Provides sound and light warnings when programmed temperature or humidity limits are exceeded.
  • External Probe Design: Main unit and sensors are separated for flexible placement and monitoring.
  • USB Data Interface: Allows configuration, data download and report management through compatible software.
  • Adjustable Logging Interval: Recording intervals can be configured from 10 seconds to 24 hours.
  • Report Export: Historical data can be analyzed and exported in common report formats.
Working Principle External sensors continuously detect temperature and humidity conditions at the monitoring location. The data logger converts the sensor signals into digital readings and records them automatically according to the programmed logging interval.

When a measured value exceeds the preset upper or lower alarm limit, the unit can provide audible and visual warnings. Recorded information can be transferred through USB to compatible computer software for graphing, historical analysis, printing and report export.
Technical Specifications
Brand Elitech
Model GSP-6
Product Type Temperature & Humidity Data Logger
Temperature Range -40°C to +85°C
Temperature Accuracy ±0.5°C from -20°C to +40°C; ±1°C Outside This Range
Humidity Range 10–99% RH
Humidity Accuracy ±3% RH at 25°C and 20–90% RH; ±5% RH Outside This Range
Temperature Resolution 0.1°C
Humidity Resolution 0.1% RH
Record Capacity Up to 16,000 Records
Logging Interval 10 Seconds to 24 Hours, Adjustable
Display 2.8-Inch LCD
Alarm Audible and Visual Over-Limit Alarm
Data Interface USB
Sensor Configuration External Temperature Probe and Temperature-Humidity Probe
Optional Probe Buffered Vaccine Temperature Probe
Dimensions 118 × 61.5 × 19 mm
Power Supply 3.6 V Wide-Temperature Lithium Battery
Applications
  • Livestock barn environmental monitoring
  • Pig, cattle, goat-farming-equipment/" target="_blank" class="keylink">sheep and poultry farm temperature monitoring
  • Veterinary vaccine refrigerators
  • Animal medicine storage
  • Farm laboratories
  • Cold rooms and refrigerated storage
  • Feed and biological product storage
  • Cold-chain transportation monitoring
  • Breeding and artificial insemination laboratories
  • Temperature and humidity quality-control records
Installation & Maintenance
  • Connect the required external temperature or temperature-humidity probe to the correct sensor port.
  • Install compatible data management software before configuring the logger through USB.
  • Set the recording interval, temperature and humidity limits, alarm mode and other monitoring parameters before use.
  • Position the external probe at a representative monitoring location while keeping the main unit accessible for reading.
  • Use the optional buffered probe for vaccine or pharmaceutical refrigerator monitoring when required.
  • Check the LCD regularly for current readings, alarm status and remaining recording capacity.
  • Download and save historical data before clearing or reconfiguring the logger.
  • Keep sensor connectors and USB ports clean and dry.
  • Avoid strong impacts, excessive moisture and corrosive cleaning chemicals.
  • Replace the battery according to the operating instructions when low power is indicated.
Product FAQ

Q: Does the GSP-6 record both temperature and humidity?
A: Yes. It supports temperature and relative humidity monitoring using compatible external sensors.

Q: What is the temperature measurement range?
A: The specified temperature range is -40°C to +85°C.

Q: What is the humidity measurement range?
A: The specified relative humidity range is 10–99% RH.

Q: How many records can it store?
A: The logger can store up to approximately 16,000 records.

Q: Can the recording interval be adjusted?
A: Yes. The interval can be configured continuously from 10 seconds to 24 hours.

Q: Does it provide an alarm when temperature or humidity exceeds the limit?
A: Yes. Programmable limits can trigger audible and visual alarm indications.

Q: Is it suitable for vaccine refrigerator monitoring?
A: Yes. An optional buffered temperature probe can be used to reduce the influence of short-term temperature fluctuations during vaccine storage monitoring.

Q: Can recorded data be exported?
A: Yes. Data can be transferred through USB to compatible software for analysis, graphing, printing and report export.

温度记录仪器 温度记录仪器

Comments & Inquiries

Leave your questions or requirements below. We will reply as soon as possible.