Global Livestock Equipment Manufacturer & Supplier
SHEWUYOU · Livestock Equipment
Integrated Equipment Solutions for Pig, Cattle & Poultry Farms

F9 V-Bank Air Filter for Livestock Ventilation

Product Showcase Content
Product Name F9 V-BANK MEDIUM-HIGH EFFICIENCY AIR FILTER
Product Image F9 V-Bank Medium-High Efficiency Air Filter
Product Overview The F9 V-Bank Medium-High Efficiency Air Filter is designed for livestock-house fresh-air filtration and other high-air-volume ventilation systems. Its compact V-bank arrangement provides a large effective filtration area within a relatively small installation space.

Glass fiber, synthetic fiber and nano-composite filter media are available according to project requirements. With filtration efficiency up to F9 under EN779 classification, the filter provides a practical balance of filtration performance, airflow resistance, dust-holding capacity and service life.
Product Gallery
  • Compact V-bank filter structure
  • Large effective filtration area
  • Multiple filter media options
  • Suitable for modular filter-wall installation
  • High dust-holding capacity and stable filtration performance
  • Designed for livestock-house fresh-air filtration systems
Key Features
  • Up to F9 Filtration: Filtration efficiency is available up to F9 according to the listed EN779 classification.
  • V-Bank Configuration: Multiple filter packs arranged in a V shape increase effective filter area without requiring excessive installation depth.
  • Low Airflow Resistance: Large media area helps maintain efficient airflow while providing fine-particle filtration.
  • High Dust-Holding Capacity: Expanded filtration area allows the filter to retain more airborne particulate matter before replacement is required.
  • Multiple Media Options: Glass fiber, synthetic fiber and nano-composite filtration media can be selected according to application requirements.
  • Moisture-Resistant Construction: Designed for stable operation in demanding ventilation environments with changing humidity conditions.
  • Stable Efficiency: Filter media are selected for consistent performance without relying on temporary electrostatic charging.
  • Compact Modular Design: Lightweight box-type construction simplifies installation and replacement in filter walls and ventilation cabinets.
Working Principle Ventilation fans create airflow through the V-bank filter. As incoming air passes through the pleated filter media, airborne dust and fine particulate matter are captured within the fiber structure while filtered air continues into the livestock-house ventilation system.

The V-bank arrangement provides a larger media surface than a flat filter of similar face dimensions. This helps reduce face velocity across the filter media, supports lower pressure drop and increases dust-holding capacity.
Technical Specifications
Product Type V-Bank Medium-High Efficiency Air Filter
Filter Configuration V-Bank / Box-Type
Filtration Grade Up to F9 (EN779)
Filter Media Options Glass Fiber / Synthetic Fiber / Nano-Composite Fiber
Performance Characteristics High Efficiency, Low Resistance, High Dust-Holding Capacity
Moisture Resistance Designed for Humid Ventilation Environments
Electrostatic Dependence Non-Electrostatic Filtration Performance
Rated Airflow According to Filter Size and Selected Configuration
Initial Pressure Drop According to Filtration Grade, Media and Rated Airflow
Dimensions Standard and Customized Sizes Available According to Project Requirements
Main Application Livestock House Fresh-Air and Ventilation Filtration
Applications
  • Pig house fresh-air filtration systems
  • Breeding and multiplication farms
  • Farrowing and nursery buildings
  • Poultry-house ventilation systems
  • Livestock-house air filter walls
  • Positive-pressure fresh-air systems
  • Multi-stage farm air filtration systems
  • High-air-volume ventilation equipment
  • Biosecurity-oriented livestock ventilation projects
Installation & Maintenance
  • Confirm filter size, airflow direction and filtration grade before installation.
  • Install the filter securely in the filter frame or air-filtration wall with an effective perimeter seal.
  • Prevent unfiltered air from bypassing the filter through gaps around the frame.
  • Use a suitable pre-filter upstream where dust loading is high to extend the service life of the V-bank filter.
  • Monitor pressure drop across the filtration system during operation.
  • Inspect filters regularly for dust loading, moisture damage, deformation or seal failure.
  • Replace the filter when the specified final resistance is reached or when airflow performance becomes inadequate.
  • Avoid damaging or compressing the filter media during handling and installation.
  • Keep replacement filters dry, clean and sealed before installation.
  • Dispose of used filters according to farm biosecurity and local waste-handling requirements.
Product FAQ

Q: What filtration efficiency is available?
A: The current product specification lists filtration efficiency up to F9 according to EN779.

Q: What filter media are available?
A: Glass fiber, synthetic fiber and nano-composite fiber media are available according to application requirements.

Q: Why use a V-bank structure?
A: The V-bank arrangement provides a larger effective filtration area within a compact housing, supporting high airflow, lower resistance and increased dust-holding capacity.

Q: Is this filter suitable for pig farms?
A: Yes. It can be incorporated into fresh-air and multi-stage filtration systems for pig houses and other livestock buildings.

Q: Can it be used after a primary pre-filter?
A: Yes. In multi-stage filtration systems, installing a coarse pre-filter upstream can reduce dust loading and extend the service life of the higher-efficiency V-bank filter.

Q: How do I know when the filter should be replaced?
A: Replacement should be based on pressure-drop monitoring, airflow performance, visible condition and the final-resistance recommendation for the selected filter configuration.

Q: Are different sizes available?
A: Yes. Filter dimensions and airflow capacity can be selected according to the ventilation system and filter-wall design.

Q: What information is required for selection?
A: Please provide the required filtration grade, filter dimensions, ventilation airflow, available installation depth and the configuration of upstream and downstream filtration stages.

Comments & Inquiries

Leave your questions or requirements below. We will reply as soon as possible.