Global Livestock Equipment Manufacturer & Supplier
SHEWUYOU · Livestock Equipment
Integrated Equipment Solutions for Pig, Cattle & Poultry Farms

Universal Bovine & Small Ruminant AI Pipette

Product Name Universal Bovine and Small Ruminant AI Pipette
Product Image bovine artificial insemination applicator
Product Overview The Universal Bovine and Small Ruminant AI Pipette is designed for controlled semen delivery in artificial insemination programs for cattle, goat-farming-equipment/" target="_blank" class="keylink">sheep and goats. Its slender shaft, application-specific tip and adaptable semen connection support practical handling by trained breeding technicians. Configurations can be developed for semen straws, Minitubes or syringe-based liquid semen systems according to the target species and insemination protocol. :contentReference[oaicite:1]{index=1}
Key Features
  • Species-oriented configurations for bovine and small ruminant artificial insemination.
  • Slender, lightweight construction supports controlled positioning during insemination.
  • Tip geometry can be adapted to the selected AI technique and reproductive anatomy.
  • Compatible configurations can accommodate semen straws, Minitubes or syringe-based semen delivery.
  • Suitable for intracervical AI in small ruminants when used with appropriate visual control equipment.
  • Can be configured for professional breeding centers, commercial livestock farms and AI service providers.
  • Customizable length, tip design, connector and packaging according to project requirements.
  • Suitable for OEM and bulk procurement programs for livestock equipment distributors.
Structural Components
  • AI Pipette Shaft: A narrow tubular body designed for controlled insertion and semen passage.
  • Insertion Tip: Smooth, rounded, eccentric or application-specific tip configurations can be supplied according to species and procedure.
  • Semen Connection: Connector or adapter for the selected semen straw, Minitube or syringe system.
  • Adapter / Tubing: Optional configuration for liquid semen supplied from a syringe.
  • Support or Stylet: Available for selected configurations requiring controlled straw positioning or semen delivery.
Working Principle / Structural Principle The AI pipette provides a controlled passage for semen from the selected dose container to the reproductive tract. For small ruminants, an eccentric-tip pipette can be used for intracervical AI under visual control with a suitable speculum. Depending on the configuration, the pipette can accept 0.25 ml or 0.5 ml semen straws, Minitubes or fresh semen supplied through a syringe and adapter. Bovine configurations can be matched with the applicable AI gun and sheath system. :contentReference[oaicite:2]{index=2}
Technical Specifications
Application Artificial insemination of cattle, sheep and goats
AI Method According to species and project requirements
Semen Format 0.25 ml or 0.5 ml straws, Minitubes, or syringe-based liquid semen according to configuration
Tip Design Smooth, rounded, eccentric or customized tip
Pipette Length Customizable according to project requirements
Material Medical or laboratory-grade polymer; exact material available upon request
Packaging Individual or bulk packaging according to project requirements
Sterility Sterilized or non-sterile configuration available upon request
OEM Configuration Customizable
Applications Suitable for commercial dairy farms, beef cattle breeding programs, sheep and goat farms, livestock breeding centers, artificial insemination stations, genetic improvement programs and agricultural project procurement. Small-ruminant configurations are particularly suitable for controlled intracervical AI procedures, while bovine configurations can be integrated with compatible AI gun and sheath systems. :contentReference[oaicite:3]{index=3}
Customization Options OEM and project-based customization is available for livestock equipment distributors, breeding organizations, agricultural engineering companies and large commercial farms. Customizable items include pipette length, outer diameter, tip geometry, eccentric tip position, connector type, tubing arrangement, material, color, packaging, labeling and private-label branding. Configurations can be developed according to local breeding practices, animal species and project requirements.
Installation & Maintenance
  1. Select the pipette configuration appropriate for the animal species and approved insemination procedure.
  2. Maintain strict hygiene and follow the farm or breeding center biosecurity SOP before handling the device.
  3. Connect the semen straw, Minitube or syringe adapter securely according to the selected configuration.
  4. For small-ruminant intracervical AI, use the appropriate speculum and visual-control procedure where required.
  5. Introduce the pipette carefully and avoid excessive force or unnecessary manipulation.
  6. Deliver the semen dose in accordance with the breeding technician's established protocol.
  7. Disposable configurations should be discarded after use. Reusable versions, if supplied, should be cleaned and disinfected according to the applicable maintenance procedure.
Project Cases Designed for integration into commercial livestock breeding projects, AI stations, dairy and beef breeding programs, sheep and goat multiplication farms, genetic improvement centers and agricultural equipment supply packages. Bulk procurement, OEM packaging and species-specific configurations can be coordinated with farm engineering schedules and centralized purchasing programs.
Product FAQ

Q: Which animals can use this AI pipette?
A: The product is designed for bovine and small-ruminant AI applications, with the final configuration selected according to species and insemination method.

Q: Can it be used with semen straws?
A: Compatible configurations can be supplied for 0.25 ml and 0.5 ml straws. Minitube compatibility is also available for suitable small-ruminant configurations.

Q: Can fresh liquid semen be used?
A: Yes, suitable configurations can be connected to fresh semen supplied through a syringe and adapter.

Q: Is an eccentric tip available?
A: Yes. An eccentric-tip configuration is available for suitable small-ruminant intracervical AI applications.

Q: Can the pipette be customized for OEM projects?
A: Yes. Length, tip design, connector, material, packaging, labeling and other project-specific requirements can be customized according to order specifications.

Product Gallery
 
bovine artificial insemination applicator
 

Comments & Inquiries

Leave your questions or requirements below. We will reply as soon as possible.